The product selection table below shows all standard mainframe units for the Series G2. These are designed to accept Series G2 modules into the rear facing module bay. Four basic types deliver a choice of four module bay sizes; 4-slot, 6-slot, 12-slot and 16-slot.
- NOTE 1: All but the 4-slot versions include dual AC power inlets.
- NOTE 2: The 12-slot and 16-slot versions include PFC supplies (power factor correction).
2RU
Four-Slot Mainframe
2RU Configuration Template
|
|
|
Model
|
Spec
Sheet |
Module
Slots
|
Height
(Rack Units)
|
Built-in
Interfaces
|
C710
Interface CPU Slots |
Power
Supply
Voltages |
Redundant
Supplies
|
G2S400CE-100 |
|
4 |
3.50
(2RU) |
GPIB
RS-232
RS-422
RS-485
Ethernet
US-Link |
None |
+/-15, +5V |
No |
G2S400CE-200 |
|
4 |
3.50
(2RU) |
GPIB
RS-232
RS-422
RS-485
Ethernet
US-Link |
None |
+/-5, +5V |
No |
G2S400CE-600 |
|
4 |
3.50
(2RU) |
GPIB
RS-232
RS-422
RS-485
Ethernet
US-Link |
None |
+15, +5V |
No |
G2S400CE-D100 |
|
4 |
3.50
(2RU) |
GPIB
RS-232
RS-422
RS-485
Ethernet
US-Link |
None |
+/-15, +5V |
Yes |
G2S400CE-D200 |
|
4 |
3.50
(2RU) |
GPIB
RS-232
RS-422
RS-485
Ethernet
US-Link |
None |
+/-5, +5V |
Yes |
G2S400CE-D600 |
|
4 |
3.50
(2RU) |
GPIB
RS-232
RS-422
RS-485
Ethernet
US-Link |
None |
+15, +5V |
Yes |
|
|
3RU
Six-Slot Mainframe
3RU Configuration Template
|
|
|
Model
|
Spec
Sheet |
Module
Slots
|
Height
(Rack Units)
|
Built-in
Interface
|
C710
Interface CPU Slots |
Power
Supply
Voltages |
Redundant
Supplies
|
G2S600CE-100 |
|
6 |
5.25
(3RU) |
None |
1 |
+/-15, +5V |
No |
G2S600CE-200 |
|
6 |
5.25
(3RU) |
None |
1 |
+/-5, +5V |
No |
G2S600CE-600 |
|
6 |
5.25
(3RU) |
None |
1 |
+15, +5V |
No |
G2S600CE-D100 |
|
6 |
5.25
(3RU) |
None |
1 |
+/-15, +5V |
Yes |
G2S600CE-D200 |
|
6 |
5.25
(3RU) |
None |
1 |
+/-5, +5V |
Yes |
G2S600CE-D600 |
|
6 |
5.25
(3RU) |
None |
1 |
+15, +5V |
Yes |
|
|
6RU
Twelve-Slot Mainframe
6RU Configuration Template
|
|
|
Model
|
Spec
Sheet |
Module
Slots
|
Height
(Rack Units)
|
Built-in
Interface
|
C700
Interface CPU Slots |
Power
Supply
Voltages |
Redundant
Supplies
|
G2S1200CE-100 |
|
12 |
10.50
(6RU) |
None |
2 |
+/-15, +5V |
No |
G2S1200CE-200 |
|
12 |
10.50
(6RU) |
None |
2 |
+/-5, +5V |
No |
G2S1200CE-600 |
|
12 |
10.50
(6RU) |
None |
2 |
+15, +5V |
No |
G2S1200CE-D100 |
|
12 |
10.50
(6RU) |
None |
2 |
+/-15, +5V |
Yes |
G2S1200CE-D200 |
|
12 |
10.50
(6RU) |
None |
2 |
+/-5, +5V |
Yes |
G2S1200CE-D600 |
|
12 |
10.50
(6RU) |
None |
2 |
+15, +5V |
Yes |
|
|
8RU
Sixteen-Slot Mainframe
8RU Configuration Template
|
|
|
Model
|
Spec
Sheet |
Module
Slots
|
Height
(Rack Units)
|
Built-in
Interface
|
C700
Interface CPU Slots |
Power
Supply
Voltages |
Redundant
Supplies
|
G2S1600CE-100 |
|
16 |
14.00
(8RU) |
None |
2 |
+/-15, +5V |
No |
G2S1600CE-200 |
|
16 |
14.00
(8RU) |
None |
2 |
+/-5, +5V |
No |
G2S1600CE-600 |
|
16 |
14.00
(8RU) |
None |
2 |
+15, +5V |
No |
G2S1600CE-D100 |
|
16 |
14.00
(8RU) |
None |
2 |
+/-15, +5V |
Yes |
G2S1600CE-D200 |
|
16 |
14.00
(8RU) |
None |
2 |
+/-5, +5V |
Yes |
G2S1600CE-D600 |
|
16 |
14.00
(8RU) |
None |
2 |
+15, +5V |
Yes |